IMPORTANT NOTICE

The pressures specified in this document are to be used as a guide only, not as a standard, specification or guaranteed minimum.

Many factors influence the pressure at which a system will operate. These factors include torque settings, alignment, vigration, external environment, correctness of installation, alignment, adequate support, temperature limits, pressures and pulses.

The Maximum Rated Working Pressure on an assembly or installation is the Maximum Rated Working Pressure of the component/connection with the least rating.

Browse data below or download the PDF file – Tech-Connection Pressure Tables.

BSPT      
DashMale FixedMale SwivelFemale Fixed
BarPSIBarPSIBarPSI
-02690100005508000
-04650950026037505508000
-06550800020030005207500
-08410600017025003805500
-10340500017025002754000
-12340500017025002754000
-1627540002403500
-2020030002003000
-2414020001752500
-3214020001402000
BSPP      
DashMale EncapsulatedMale AdjustableFemale Swivel
BarPSIBarPSIBarPSI
-02600870027540005508000
-04600870027540005508000
-06600870027540005207500
-08400600027540003805500
-12400600017025002754000
-16400600017025002403500
-20380550014020002003000
-24380550014020001752500
-3225035001402000
JIC    
DashMaleFemale
BarPSIBarPSI
-0748070004807000
-0848070004807000
-0934550003455000
-1227540002754000
-1426038002603800
-1724035002403300
-2122530002253500
-2617025001702500
-3014521001452100
-4012017501201750
NPT      
DashMale FixedMale SwivelFemale Fixed
BarPSIBarPSIBarPSI
-02690100005508000
-04650950026037505508000
-06550800020030005207500
-08410600017025003805500
-12340500017025002754000
-1627540002403500
-2020030002003000
-2414020001752500
-3214020001402000
SAE Flange    
DashCD 61CD 62
BarPSIBarPSI
-0834550004106000
-1234550004106000
-1634550004106000
-2027540004106000
-2420530004106000
-3220530004106000
JIS (Komatsu)    
DashMaleFemale
BarPSIBarPSI
-14(M)45065004106000
-16(M)45065004106000
-22(M)41060003805500
-24(M)34550003104500
-30(M)27540002603750

Connector Pressure Tables